Any recommendations for backup generator? - Dorkiphus.net
Navigation » Dorkiphus.net > Miscellaneous Discussions > Miscellaneous Discussions » Any recommendations for backup generator?

Miscellaneous Discussions Off Topic (OT) items that really don't fit into any other Category

Reply
 
Thread Tools Display Modes
  #1  
Old 01-04-2021, 11:37 AM
Mark Hubley's Avatar
Mark Hubley Mark Hubley is offline
 
Join Date: Oct 2010
Location: Dunkirk, MD
Posts: 834
Mark Hubley
Default Any recommendations for backup generator?

This is long overdue, but I think my wife is finally ready to shell out the $$$ for a backup generator for her veterinary clinic. The type that comes on automatically when power goes out. I assume she will need something more robust that what you might get for the typical house, but then we're not powering something the size of the Pentagon.

Any recommendations?
__________________
2015 Cayman GTS
2021 Jetta R-line
2016 F-250

Formerly owned Porsche/BMW:
1986 944 Turbo
2006 325i
2000 911
1987 924S
1999 Boxster
1986 944
Reply With Quote
  #2  
Old 01-04-2021, 11:58 AM
cmartin's Avatar
cmartin cmartin is offline
 
Join Date: Sep 2003
Location: Pasadena, MD
Posts: 7,582
cmartin
Default

What fuel? Do you have nat gas available?
__________________
78 SC, the 'Red Car'
Reply With Quote
  #3  
Old 01-04-2021, 12:24 PM
Mark Hubley's Avatar
Mark Hubley Mark Hubley is offline
 
Join Date: Oct 2010
Location: Dunkirk, MD
Posts: 834
Mark Hubley
Default

Quote:
Originally Posted by cmartin View Post
What fuel? Do you have nat gas available?
We don't have any gas at this time. However, I believe you can get these things with tanks (LP?) that get filled as needed. Is that correct?
__________________
2015 Cayman GTS
2021 Jetta R-line
2016 F-250

Formerly owned Porsche/BMW:
1986 944 Turbo
2006 325i
2000 911
1987 924S
1999 Boxster
1986 944
Reply With Quote
  #4  
Old 01-04-2021, 01:02 PM
racer's Avatar
racer racer is offline
 
Join Date: Jul 2004
Location: South Riding, Va
Posts: 7,219
racer
Default

"Generac" is the name I see on TV with back up power supply equipment.
__________________
Dave
- 1970 914-6
Past
- 2000 Boxster
- 1987 944
- 1987 924S
- 1978 911 Euro SC
- 1976 914 2.0
- 1970 914 1.7 / 2056cc
Reply With Quote
  #5  
Old 01-04-2021, 01:11 PM
cmartin's Avatar
cmartin cmartin is offline
 
Join Date: Sep 2003
Location: Pasadena, MD
Posts: 7,582
cmartin
Default

You can get a propane tank, I have a buried one. Another option is diesel, but will need tanks tool. What service level do you need? Only a few lights, run the xray machines? How many amps service now? What is your expected run time on the gen? Just a few minutes/hours maybe once in a while? Be ready for days on end of use?
__________________
78 SC, the 'Red Car'
Reply With Quote
  #6  
Old 01-04-2021, 01:17 PM
dnwong's Avatar
dnwong dnwong is offline
 
Join Date: Jun 2006
Location: Aldie, VA
Posts: 816
dnwong
Default

You are going to need a transfer switch tied in the existing panel. I assume this is a commercial building.
__________________
Dudley
Aldie, VA
99 996 C4 Black/Black Areo
86 951 Graphite / Burgundy
2002 BMW 530i
2008 Volvo XC90
1995 Chev Astro (workhorse going-bald)
My Garage Build
Reply With Quote
  #7  
Old 01-04-2021, 01:55 PM
BillC's Avatar
BillC BillC is offline
 
Join Date: Aug 2008
Location: Silver Spring, MD
Posts: 1,236
BillC has one HoF thread
Default

We had a whole-house automatic backup generator installed about 15 or so years ago. For the most part, it's been very nice.

Some things to keep in mind:
  • There are two big brand names in residential fixed-site backup generators: Kohler and Generac.
  • Based on our experience with our Generac generator, I strongly recommend that you look at getting a Kohler generator. Mechanically, the Generac has been solid, but the control electronics aren't the most durable -- we've had to replace the computer once already.
  • Both Kohler and Generac require that the generator and transfer panel be installed by an approved contractor, or they/you won't be able to install the "automatic start/stop" software patch.
  • Once installed, any good electrical contractor can do the maintenance on the generator, if you decide you don't want to do it yourself. The factory-approved contractors tend to be significantly more expensive for maintenance than the non-approved ones.
  • Look at getting a generator big enough to run everything, for two reasons:
    - It's very convenient to have everything be powered, instead of regretting getting a too-small generator later on.
    - It's easier to use the current main breaker panel as the daughter panel from the new transfer switch. Otherwise, you'll need to install a new box and transfer over all the circuits that will be backed up.
__________________
2016 GT4 warp 7
1999 SPB warp 2, maybe
1973 914 2.0 1/2 impulse if it ever gets out of space dock

Previous:
1973 914 1.7 1/4 impulse
2012 Cayman R warp 4
2006 Cayman S warp 3
1999 SPB warp 2, maybe
1966 911 warp 1.5

Last edited by BillC; 01-04-2021 at 02:03 PM.
Reply With Quote
  #8  
Old 01-04-2021, 01:58 PM
BlackTalon's Avatar
BlackTalon BlackTalon is offline
Make Dorki Great Again
 
Join Date: Dec 2002
Location: Alexandria, Virginia
Posts: 14,796
BlackTalon
Default

Check local building codes and zoning ordinances to see where it is okay to install. May not be able to ground-mount it wherever. Or roof mounting, they could require a screen wall, etc. Could be worth a visit to the county permitting and/ or zoning office to ask.
__________________
David D.
'87 Targa

- 2021 quickly disappearing...
Reply With Quote
  #9  
Old 01-04-2021, 02:31 PM
Vicegrip's Avatar
Vicegrip Vicegrip is offline
Porkchop & SGB for prez!
 
Join Date: Jan 2003
Location: The other Woodstock.
Posts: 13,240
Vicegrip has seven HoF threadsVicegrip has seven HoF threadsVicegrip has seven HoF threadsVicegrip has seven HoF threadsVicegrip has seven HoF threadsVicegrip has seven HoF threads
Default

I deal with them all the time. Need to start an idea of size first. Little one to keep the lights on or 100% power replacement? What is your source of heat in the winter? Do you house animals on site?

Natural gas is a good fuel as it does not gum up when the system sits. It is a double edged sword I it has an unlimited fuel supply if the lines are good but no fuel or way to bypass if the lines are not good.
Diesel is good if you want long run times and don’t have natural gas. (I have a big diesel whole house and 6 weeks of 24/7 fuel)
Stabilized property diesel fuel can last well. It has some downsides. You have to run it now and then and it is hard to start in the deep cold. I run it once a week for 20 min and twice a year I switch over to have it run the house. It is hard to start when it is real cold. The set is environmentally boxed and has its own shed.
Propane is a good alt if natural gas is not available. All the good aspects of non gumming fuel but you have to have a tank installed somewhere.
Gasoline is the least favorite of the bunch for long term full load systems due to the fuel itself. That said it can work if the setup is done well.
You see it have a timed exerciser to run it once a week and you need to service it now a d then of it will fail on you when you need it. Trust me, I have had far too many calls for non running backup generators when the power is out.
__________________
http://vimeo.com/29896988

“Those that can make you believe in absurdities can make you commit atrocities.” Voltaire.

"There is grandeur in this view of life...." Darwin.

The mountains are calling and I must go.

“The earth has music for those who listen”
Shakespeare.

You Matter.
(Until you multiply yourself times the speed of light squared. Then you Energy)

“We’ve got lots of theories, we just don’t have the evidence’.
Reply With Quote
  #10  
Old 01-04-2021, 04:41 PM
Mark Hubley's Avatar
Mark Hubley Mark Hubley is offline
 
Join Date: Oct 2010
Location: Dunkirk, MD
Posts: 834
Mark Hubley
Default

I don't know all the specs (such as a number for the power requirement), and I assume that will be reviewed with the contractor. Here's what I can tell you for now . . .

For a few years now Susan and her team have been doing full-fledged surgeries on horses. We don't have frequent power outages, but I think she's been lucky we haven't had some sort of issue in the middle of a procedure.

1. I figure we need to be prepared to function on backup for 48 hours, or maybe a few days.

2. I think it makes sense to have something that can pretty much power the whole facility: lights, HVAC (two heat pumps), well pump, computers, equipment, etc.

3. Something that comes on more-or-less instantly will be nice.

We have a pigtail that I can plug into with a portable generator, and then I have to pick and choose what to turn on/off. That has gotten us through multiple power outages over the past fifteen years, but we are past the point where we need something better than that.
__________________
2015 Cayman GTS
2021 Jetta R-line
2016 F-250

Formerly owned Porsche/BMW:
1986 944 Turbo
2006 325i
2000 911
1987 924S
1999 Boxster
1986 944
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump