Default Electrician recommendation for MD?

Apologies in advance to Andy for asking a non-automotive question, but maybe even he can provide some advice on this one.

Can anyone recommend an electrician in the Gaithersburg/Germantown vicinity to do some troubleshooting on my house? I have a GFI wired to an outside light and some bathroom and basement receptacles that keeps tripping (~weekly), but this evening worried me a little more.

This evening, with a space heater hooked up to that circuit, I got a strong burning smell elsewhere in the house. It smelled like my wife was burning dinner but she wasn't even in the kitchen (maybe her powers are just that wonderous). The smell went away when I turned off the heater but not certain the heater was the cause. The smell originated on the first floor directly above the basement circuit panel but there was no smell in the basement itself. The GFI reset on that circuit is right under the panel. Any ideas? I turned the breaker off later just to be safe.

House was built in '95 and all wiring is original.

Thanks in advance for any recommendations or advice.

Later,
Jerome
__________________
Jerome Welte
'97 Spec Boxster
'20 Nissan Titan XD
'02 BMW 330i convertible
Reply With Quote
  #2  
Old 11-11-2008, 07:10 PM
washington dc porsche's Avatar
washington dc porsche washington dc porsche is offline
Freeloader
 
Join Date: Jul 2005
Location: Prince George's County
Posts: 203
washington dc porsche
Default

I'm not an electrician but have you noticed if the circuit breaker in the panel is warm or warmer than the other circuit breakers? If so, it shouldn't be.


Quote:
Originally Posted by jerome951 View Post
Apologies in advance to Andy for asking a non-automotive question, but maybe even he can provide some advice on this one.

Can anyone recommend an electrician in the Gaithersburg/Germantown vicinity to do some troubleshooting on my house? I have a GFI wired to an outside light and some bathroom and basement receptacles that keeps tripping (~weekly), but this evening worried me a little more.

This evening, with a space heater hooked up to that circuit, I got a strong burning smell elsewhere in the house. It smelled like my wife was burning dinner but she wasn't even in the kitchen (maybe her powers are just that wonderous). The smell went away when I turned off the heater but not certain the heater was the cause. The smell originated on the first floor directly above the basement circuit panel but there was no smell in the basement itself. The GFI reset on that circuit is right under the panel. Any ideas? I turned the breaker off later just to be safe.

House was built in '95 and all wiring is original.

Thanks in advance for any recommendations or advice.

Later,
Jerome
Reply With Quote
  #3  
Old 11-11-2008, 07:49 PM
matt de maria matt de maria is offline
 
Join Date: May 2004
Location: gaithersburg,md
Posts: 555
matt de maria has one HoF thread
Default

Call me. My electrician lives in Derwood.
Reply With Quote
  #4  
Old 11-11-2008, 08:17 PM
Landjet Landjet is offline
 
Join Date: Mar 2007
Posts: 2,917
Landjet
Default

Jarome, I have been in the construction arena for 30 years and although I'm not an electrician and don't know any around here, I do know from experience that you should not use that circuit again until you do get an electrician to check it out. You could risk a house fire. You might also double check that heater. Sounds like there was some kind of short or overload, but an overload should have tripped the breaker. Have you looked for any evidence of moisture or water in or around the receptacles that are tripping because GFI is usually water sensitive. That's why they are normally in bathrooms. If you already know all this, please excuse.
Reply With Quote
  #5  
Old 11-11-2008, 09:05 PM
Andy Clements's Avatar
Andy Clements Andy Clements is offline
Rusty Grinderschmütz
 
Join Date: Dec 2004
Location: Usually the dirty side of a 944
Posts: 765
Andy Clements
Default

I'll excuse the off topic. Larry is right....get it checked out...don't risk it. GFI's are very sensitive devices, and they can "go bad" over time....especially if original. There is also a good chance that moisture is finding its way into the system somewhere.....maybe in the outside light, a junction box leak, an outdoor receptacle with a bad seal....lots of possibilities. If the smell wasn't localized to the heater, chances are that it was heating up the circuit enough that the mysterious weak link was getting hot/smelly. Get it checked out. If you don't find somebody to check it out, let me know and I may be able to dig up a name I could PM you.
__________________
Andy
'84 944 DE Car
Reply With Quote
  #6  
Old 11-11-2008, 09:45 PM
OldTee's Avatar
OldTee OldTee is offline
 
Join Date: Jan 2004
Location: Derwood, MD
Posts: 3,618
OldTee has one HoF thread
Default

Quote:
Originally Posted by matt de maria View Post
Call me. My electrician lives in Derwood.

He has done some work for me. X2 good.
ARF
__________________
OldTee
Sold 79 911SC
1/2 87 Carrera (I fix daughter drives)
1991 Corvette
Need locks don't use H & H Lock Company
Capital One is the pits!
Reply With Quote
  #7  
Old 11-11-2008, 10:03 PM
86911TLCAB 86911TLCAB is offline
Tito
 
Join Date: Nov 2005
Location: Bristow VA
Posts: 2,192
86911TLCAB
Default

Had a similar problem with a gfi circuit tripping which was tied to the outside lamp. I opened up the lamp and cleaned out all the dead bugs and the glass...did a reseal on the areas where water might be getting in...hasnt happened in a while...good idea to also have it checked out.
__________________
Tito

82 911 SC with 3.2
73 RSR project
97 328is
99 328is
97 Lexus SC300 Manual

86 TL (gone)
993 (gone)
75 911S (gone)
Reply With Quote
  #8  
Old 11-12-2008, 12:44 AM
Vicegrip's Avatar
Vicegrip Vicegrip is offline
Porkchop & SGB for prez!
 
Join Date: Jan 2003
Location: The other Woodstock.
Posts: 13,278
Vicegrip has seven HoF threadsVicegrip has seven HoF threadsVicegrip has seven HoF threadsVicegrip has seven HoF threadsVicegrip has seven HoF threadsVicegrip has seven HoF threads
Default

Sounds like a loose connection in a hot (black or red in 120V Red being switched) or neutral (white) wires between the heater and circuit breaker. Open up the breaker panel and look and pull on the wire to the breaker involved and then do the same with all devices down stream. Snap the breaker on and off a time or two remove the breaker and smell it. (They snap in and out with no tools in most residential service panels) They go bad from time to time too. Roasted Bakalite has a distinctive smell. Look for loose and blackened connections in all the wall boxes on any devices. The receptacles are often used as connectors with the wires running into and then back out of them to the next one. This means depending on how the house is wired it might be almost any that is on the circuit involved. Older houses with ceiling lights tend to use the ceiling light box as a junction box. Wires rarely fail in the wall, at a device connection is far more common. Check all the wire nut connections to the white wires as well. The less handy can go around and smell each outlet to see if any smell burnt. Don't let the wife and kids see you do this by the way. If you do find a stinky one get the wife point at it and with your best guy voice say "Based on my vast electrical knowledge I think it is this one"

My bet is the GFI device under the service panel used to power the line in question has a loose "Load" connection.

Just internut ramblings not advice...
__________________
http://vimeo.com/29896988

“Those that can make you believe in absurdities can make you commit atrocities.” Voltaire.

"There is grandeur in this view of life...." Darwin.

The mountains are calling and I must go.

“The earth has music for those who listen”
Shakespeare.

You Matter.
(Until you multiply yourself times the speed of light squared. Then you Energy)

“We’ve got lots of theories, we just don’t have the evidence’.
Reply With Quote
  #9  
Old 11-12-2008, 06:51 AM
jerome951 jerome951 is offline
 
Join Date: Jul 2005
Location: The slummy side of Potomac
Posts: 1,659
jerome951
Default

Thanks for all of the advice, guys. The breaker is certainly staying off until I get a pro to look at it.

I'll give Matt and John's guy a ring today. Matt, OldTee pm'd me Tim's phone number already.

I did pull the plate off the outlet closest to where I initially smelled the burning but there was no smell inside (different circuit).

I did install a new outdoor light last year but can't remember if it coincided with the GFI starting to trip. I'll pull it off and check for moisture or loose wires. The GFI seems to trip during the day while the light is off so it may not be the problem. There's an exterior junction box for it as well that I'll check.

I did have a problem a couple years ago with a similar periodic burning smell and tripping breaker. Found one of the wires had pulled out of the back of the receptacle, was laying on the bare ground wire, and had burnt it ~1/2 way through.

I grew up around residential construction (dad had a masonry firm. I had to work in the summers which is why I now have a desk job). I frequently watched electricians installing their magic smoke and tubes. I got turned off of electrical stuff, though, when at the age of ~8 I was walking through our home under construction, which had been partially wired, reached into a light switch box to pull out some drywall mud, and didn't know the circuit was hot. Knocked me on my ass.
__________________
Jerome Welte
'97 Spec Boxster
'20 Nissan Titan XD
'02 BMW 330i convertible
Reply With Quote
  #10  
Old 11-12-2008, 07:48 AM
hoophead's Avatar
hoophead hoophead is offline
 
Join Date: Aug 2006
Location: Purcellville, VA
Posts: 828
hoophead
Default

Quote:
Originally Posted by jerome951 View Post
I did have a problem a couple years ago with a similar periodic burning smell and tripping breaker. Found one of the wires had pulled out of the back of the receptacle, was laying on the bare ground wire, and had burnt it ~1/2 way through.
Seems like it's not just a local issue - I would check ALL of the receptacles in the house. At a minimum get one of those yellow outlet testers and go around and check all of the outlets. BTW I hate these "push-in" types of connections on the back of receptacles for this very reason and rewire the leads to the side screws any time I have one out. I don't like the small contact area with the wire where the push-in grips - usually you can give it a good yank and pull the wire out. Much more contact area under the screws.

Also, not all receptacles are created equal. I wired my basement with pro-grade ones that are much better constructed and provide more robust grip on plugs. Cheapo sockets start to lose their grip after just a few insertions. The pro-grade doesn't cost that much more.
__________________
Jeff S
'14 991.1 Carrera S Coupe
'25 Cayenne E-Hybrid
'11 997.2 Carrera S Cab
'09 987.2 Cayman S
'05.5 Audi S4
'25 GMC Yukon XL
'17 718 Boxster
'18 718 Cayman x 2
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump